Response H'06
 Response: H'06 (one byte): Response to user MAT programming selection
When the programming program has been transferred, the boot program will return ACK.
Error response H'C3 ERROR
 Error response: H'C3 (one byte): Error response to user MAT programming selection
 ERROR: (one byte): Error code
H'54: Selection processing error (transfer error occurs and processing is not completed)
(3) Selection of Two-User-Boot MAT Simultaneous Programming
In response to the selection of two-user-boot MAT simultaneous programming, the boot
program transfers a program for the two-user-boot MAT simultaneous programming. The
transferred program for the two-user-boot MAT simultaneous programming is used to program
data onto two user boot MATs simultaneously. Taking into account two-MAT simultaneous
write, addresses and data corresponding to the two MATs should be alternately transmitted at
the host side. Though the boot program returns ACK each time one 128-byte programming
command is given, data is not programming until data for two user boot MATs is completely
prepared.
Command H'44
 Command: Command: H'44 (one byte): Selection of two-user-boot MAT simultaneous
programming
Response H'06
 Response: H'06 (one byte): Response to the selection of two-user-boot MAT simultaneous
programming. ACK is given when the programming program has been transferred.
Error response H'C4 ERROR
 Error response: H'C4 (one byte): Error response to the selection of two-user-boot MAT
simultaneous programming
 ERROR: (one byte): Error code
H'54: Selection processing error (transfer error occurs and processing is not completed)
(4) 128-byte programming
The boot program will use the programming program transferred by the programming
selection command for programming the user boot MATs or user MATs. When two-user-
MAT simultaneous programming command is selected, programming will start after the boot
program has received data for both MATs.
Command H'50 Programming address
Data …
…
SUM
 Command: H'50 (one byte): 128-byte programming