• Bit 3—A/D Duty Flag A (ADDFxA): Indicates whether or not the ADDRxA and ADCNT
values have matched.
Bit 3:
ADDFxA
Description
0
[Clearing condition]
When ADDFxA is read while set to 1, then 0 is written to ADDFxA
1
[Setting condition]
When ADCNTx and ADDRxA values have matched
Note: x = 0 or 1.
(Initial value)
• Bit 2—A/D Cycle Compare Match Flow Flag (ADCYLFx): Indicates whether or not the
ADCYLRx and ADCNT values have matched.
Bit 2:
ADCYLFx
Description
0
[Clearing condition]
(Initial value)
When ADCYLFx is read while set to 1, then 0 is written to ADCYLFx
1
[Setting condition]
When ADCNTx and ADCYLRx values have matched
Note: x = 0 or 1.
• Bit 1—A/D Compare Match Flag (ADCMFxB): Indicates whether or not the ADGRxB and
ADCNT values have matched.
Bit 1:
ADCMFxB
Description
0
[Clearing condition]
(Initial value)
When ADCMFxB is read while set to 1, then 0 is written to ADCMFxB
1
[Setting condition]
When ADCNTx and ADGRxB values have matched
Note: x = 0 or 1.
Rev. 3.0, 09/04, page 659 of 1086