this reason, it is necessary to reduce the risk of damage to the flash memory by extending the reset
period so that the charge is released.
The state-transition diagram in figure 23.16 shows transitions to and from the error protection
state.
Program mode
Erase mode
Reset or standby
= 0 or
=0
(Hardware protection)
Read disabled
Programming/erasing
enabled
FLER=0
Error occurred
Er(rSorofotwccaurerresdtandby) =0 or =0
Read enabled
Programming/erasing disabled
FLER=0
=0 or
=0
Programming/erasing interface
register is in its initial state.
Error protection mode Software standby mode
Error protection mode
(Software standby)
Read enabled
Programming/erasing disabled
FLER=1
Cancel
software standby
mode
Read disabled
Programming/erasing disabled
FLER=1
Programming/erasing interface
register is in its initial state.
Figure 23.16 Transitions to and from Error Protection State