Sample Setup Procedure for Channel 0 Input Capture Triggered by Channel 10 Compare-
Match: An example of the setup procedure for compare-match signal transmission is shown in
figure 11.55.
Start
Set compare-match
Set TCR10
Start counter
1 1. Set the timing for compare-match generation in the channel
10 output compare register (OCR10B).
2. Set the TRG0DEN bit to 1 in the channel 10 timer control
register (TCR10).
3. Set the corresponding bit to 1 in the timer start register
2
(TSTR) to start the channel 10 free-running counter
(TCNT10B). On compare-match between TCNT10 and
OCR10B, the compare-match signal is transmitted to
channel 0 as the channel 0 ICR0D input capture signal.
3
Signal transmission
Figure 11.55 Sample Setup Procedure for Compare-Match Signal Transmission
Rev. 3.0, 09/04, page 403 of 1086