REGISTER 24-6: CWG1AS0: CWG AUTO-SHUTDOWN CONTROL REGISTER 0
R/W/HS/HC-0/0 R/W-0/0
R/W-0/0
R/W-1/1
R/W-0/0
R/W-1/1
U-0
SHUTDOWN
REN
LSBD<1:0>
LSAC<1:0>
—
bit 7
U-0
—
bit 0
Legend:
R = Readable bit
W = Writable bit
u = Bit is unchanged
x = Bit is unknown
‘1’ = Bit is set
‘0’ = Bit is cleared
q = Value depends on condition
U = Unimplemented bit, read as ‘0’
-n/n = Value at POR and BOR/Value at all other Resets
HS/HC = Bit is set/cleared by hardware
bit 7
bit 6
bit 5-4
bit 3-2
bit 1-0
SHUTDOWN: Auto-Shutdown Event Status bit(1,2)
1 = An auto-shutdown state is in effect
0 = No auto-shutdown event has occurred
REN: Auto-Restart Enable bit
1 = Auto-restart is enabled
0 = Auto-restart is disabled
LSBD<1:0>: CWG1B and CWG1D Auto-Shutdown State Control bits
11 = A logic ‘1’ is placed on CWG1B/D when an auto-shutdown event occurs.
10 = A logic ‘0’ is placed on CWG1B/D when an auto-shutdown event occurs.
01 = Pin is tri-stated on CWG1B/D when an auto-shutdown event occurs.
00 = The inactive state of the pin, including polarity, is placed on CWG1B/D after the required
dead-band interval when an auto-shutdown event occurs.
LSAC<1:0>: CWG1A and CWG1C Auto-Shutdown State Control bits
11 = A logic ‘1’ is placed on CWG1A/C when an auto-shutdown event occurs.
10 = A logic ‘0’ is placed on CWG1A/C when an auto-shutdown event occurs.
01 = Pin is tri-stated on CWG1A/C when an auto-shutdown event occurs.
00 = The inactive state of the pin, including polarity, is placed on CWG1A/C after the required
dead-band interval when an auto-shutdown event occurs.
Unimplemented: Read as ‘0’
Note 1: This bit may be written while EN = 0 (Register 24-1), to place the outputs into the shutdown configuration.
2: The outputs will remain in auto-shutdown state until the next rising edge of the CWG data input after this
bit is cleared.