English
Language : 

SH7047 Datasheet, PDF (327/764 Pages) Renesas Technology Corp – Renesas 32-Bit RISC Microcomputer SuperHTMRISC engine Family/SH7000 Series
Operation when Error Occurs during PWM Mode 1 Operation, and Operation is Restarted
in Complementary PWM Mode: Figure 10.95 shows an explanatory diagram of the case where
an error occurs in PWM mode 1 and operation is restarted in complementary PWM mode after re-
setting.
MTU module
output
TIOC3A
1
2
3
4
RESET TMDR TOER TIOR
(PWM1) (1) (1 init
0 out)
5
PFC
(MTU)
6
TSTR
(1)
7
8
9
10
11
12
13
14
15
16
17
Match Error PFC TSTR TMDR TIOR TIOR TOER TOCR TMDR TOER
occurs (PORT) (0) (normal) (0 init (disabled) (0)
(CPWM) (1)
0 out)
18 19
PFC TSTR
(MTU) (1)
TIOC3B
• Not initialized (TIOC3B)
TIOC3D
Port output
PE8
PE9
• Not initialized (TIOC3D)
High-Z
High-Z
PE11
High-Z
Figure 10.95 Error Occurrence in PWM Mode 1, Recovery in Complementary PWM Mode
1 to 10 are the same as in Figure 10.91.
11. Set normal mode for initialization of the normal mode waveform generation section.
12. Initialize the PWM mode 1 waveform generation section with TIOR.
13. Disable operation of the PWM mode 1 waveform generation section with TIOR.
14. Disable channel 3 and 4 output with TOER.
15. Select the complementary PWM output level and cyclic output enabling/disabling with
TOCR.
16. Set complementary PWM.
17. Enable channel 3 and 4 output with TOER.
18. Set MTU output with the PFC.
19. Operation is restarted by TSTR.
Rev. 2.00, 09/04, page 287 of 720