English
Language : 

SH7047 Datasheet, PDF (325/764 Pages) Renesas Technology Corp – Renesas 32-Bit RISC Microcomputer SuperHTMRISC engine Family/SH7000 Series
Operation when Error Occurs during PWM Mode 1 Operation, and Operation is Restarted
in PWM Mode 2: Figure 10.93 shows an explanatory diagram of the case where an error occurs
in PWM mode 1 and operation is restarted in PWM mode 2 after re-setting.
1
2
3
RESET TMDR TOER
(PWM1) (1)
MTU module
output
TIOC*A
4
TIOR
(1 init
0 out)
5
6
PFC TSTR
(MTU) (1)
7
Match
8
9
10 11 12
Error PFC TSTR TMDR TIOR
occurs (PORT) (0) (PWM2) (1 init
0 out)
13
PFC
(MTU)
14
TSTR
(1)
• Not initialized (cycle register)
TIOC*B
• Not initialized (TIOC*B)
Port output
PEn
High-Z
PEn
High-Z
n=0 to 15
Figure 10.93 Error Occurrence in PWM Mode 1, Recovery in PWM Mode 2
1 to 10 are the same as in Figure 10.91.
11. Set PWM mode 2.
12. Initialize the pins with TIOR. (In PWM mode 2, the cycle register pins are not initialized.)
13. Set MTU output with the PFC.
14. Operation is restarted by TSTR.
Note: PWM mode 2 can only be set for channels 0–2, and therefore TOER setting is not
necessary.
Rev. 2.00, 09/04, page 285 of 720