English
Language : 

SH7047 Datasheet, PDF (289/764 Pages) Renesas Technology Corp – Renesas 32-Bit RISC Microcomputer SuperHTMRISC engine Family/SH7000 Series
Overflow Interrupt: An interrupt is requested if the TCIEV bit in TIER is set to 1 when the
TCFV flag in TSR is set to 1 by the occurrence of TCNT overflow on a channel. The interrupt
request is cleared by clearing the TCFV flag to 0. The MTU has five overflow interrupts, one for
each channel.
Underflow Interrupt: An interrupt is requested if the TCIEU bit in TIER is set to 1 when the
TCFU flag in TSR is set to 1 by the occurrence of TCNT underflow on a channel. The interrupt
request is cleared by clearing the TCFU flag to 0. The MTU has four underflow interrupts, one
each for channels 1 and 2.
10.5.2 DTC Activation
The DTC can be activated by the TGR input capture/compare match interrupt in each channel. For
details, see section 8, Data Transfer Controller (DTC).
A total of 17 MTU input capture/compare match interrupts can be used as DTC activation sources,
four each for channels 0 and 3, and two each for channels 1 and 2, and five for channel 4.
10.5.3 A/D Converter Activation
The A/D converter can be activated by the TGRA input capture/compare match in each channel.
If the TTGE bit in TIER is set to 1 when the TGFA flag in TSR is set to 1 by the occurrence of a
TGRA input capture/compare match on a particular channel, a request to start A/D conversion is
sent to the A/D converter. If the MTU conversion start trigger has been selected on the A/D
converter at this time, A/D conversion starts.
In the MTU, a total of five TGRA input capture/compare match interrupts can be used as A/D
converter conversion start sources, one for each channel.
Rev. 2.00, 09/04, page 249 of 720