Table 17.29 Status Read Mode Return Commands
Pin Name FO7
FO6
Attribute
Normal
Command
end
error
identification
FO5
Program-
ming error
FO4
Erase
error
FO3*
—
Initial value 0
0
0
0
0
Indications Normal
end: 0
Abnormal
end: 1
Command Program- Erase
—
error: 1
ming
error: 1
Otherwise: 0 error: 1
Otherwise: 0
Otherwise: 0
Note: * FO2 and FO3 are undefined.
FO2*
—
0
—
FO1
FO0
Program- Effective
ming or
address error
erase count
exceeded
0
0
Count
Effective
exceeded: 1 address
Otherwise: 0 error: 1
Otherwise: 0
Status Read Mode Usage Note: After the auto-program mode or auto-erase mode has completed,
make sure to enter the status read mode before powering off the system.
The return commands are undefined immediately after power-on or if the system has been
powered off once.
17.13.8 Status Polling
• The FO7 status polling flag indicates the operating status in auto-program or auto-erase mode.
• The FO6 status polling flag indicates a normal or abnormal end in auto-program or auto-erase
mode.
Table 17.30 Status Polling Output Truth Table
Pin Names
FO7
FO6
FO0 to FO5
Internal Operation
in Progress
0
0
0
Abnormal End —
1
0
0
1
0
0
Normal End
1
1
0