English
Language : 

SH7203 Datasheet, PDF (656/1686 Pages) Renesas Technology Corp – 32-Bit RISC Microcomputer SuperHTM RISC engine Family / SH7200 Series
Section 11 Multi-Function Timer Pulse Unit 2 (MTU2)
(2) Operation when Error Occurs during Normal Mode Operation, and Operation is
Restarted in PWM Mode 1
Figure 11.114 shows an explanatory diagram of the case where an error occurs in normal mode
and operation is restarted in PWM mode 1 after re-setting.
1
2
3
RESET TMDR TOER
(normal) (1)
MTU2 module output
TIOC*A
4
5
6
TIOR PFC TSTR
(1 init (MTU2) (1)
0 out)
7
8
9
10
11
12
13
14
Match Error PFC TSTR TMDR TIOR PFC TSTR
occurs (PORT) (0) (PWM1) (1 init (MTU2) (1)
0 out)
TIOC*B
Not initialized (TIOC*B)
Port output
PEn
High-Z
PEn
High-Z
n = 0 to 15
Figure 11.114 Error Occurrence in Normal Mode, Recovery in PWM Mode 1
1 to 10 are the same as in figure 11.113.
11. Set PWM mode 1.
12. Initialize the pins with TIOR. (In PWM mode 1, the TIOC*B side is not initialized. If
initialization is required, initialize in normal mode, then switch to PWM mode 1.)
13. Set MTU2 output with the PFC.
14. Operation is restarted by TSTR.
Rev. 2.00 Apr. 16, 2008 Page 626 of 1652
REJ09B0313-0200