Section 17 ROM
Error
H'D0 ERROR
Response
• Error response, H'D0, (1 byte): Error response for 128-byte programming
• ERROR: (1 byte): Error code
H'11: Checksum error
H'2A: Address error
The address is not within the specified range.
H'53: Programming error
A programming error has occurred and programming cannot be continued.
The specified address should match the unit for programming of data. For example, when the
programming is in 128-byte units, the lower byte of the address should be H'00 or H'80.
When there are less than 128 bytes of data to be programmed, the host should fill the rest with
H'FF.
Sending the 128-byte programming command with the address of H'FFFFFFFF will stop the
programming operation. The boot program will interpret this as the end of the programming and
wait for selection of programming or erasing.
Command H'50 Address SUM
• Command, H'50, (1 byte): 128-byte programming
• Programming Address (4 bytes): End code is H'FF, H'FF, H'FF, H'FF.
• SUM (1 byte): Checksum
Response H'06
• Response: H'06 (1 byte): Response to 128-byte programming
On completion of programming, the boot program will return ACK.
Error
H'D0 ERROR
Response
• Error Response, H'D0, (1 byte): Error response for 128-byte programming
ERROR: (1 byte): Error code
H'11: Checksum error
H'53: Programming error
An error has occurred in programming and programming cannot be continued.
Rev.7.00 Feb. 14, 2007 page 773 of 1108
REJ09B0089-0700