D12320VF25V Datasheet, PDF (707/1146 Pages) Renesas Technology Corp – Old Company Name in Catalogs and Other Documents | |||
|
◁ |
Section 17 ROM
Table 17.36 Programmer Mode Commands
Command Name
Number
of Cycles Mode
1st Cycle
Address Data
2nd Cycle
Mode Address Data
Memory read mode 1 + n
Write Ã
H'00
Read RA
Dout
Auto-program mode 129
Write Ã
H'40
Write PA
Din
Auto-erase mode
2
Write Ã
H'20
Write Ã
H'20
Status read mode 2
Write Ã
H'71
Write Ã
H'71
Legend:
RA: Read address
PA: Program address
Ã: Donât care
Notes: 1. In auto-program mode, 129 cycles are required for command writing by a simultaneous
128-byte write.
2. In memory read mode, the number of cycles depends on the number of address write
cycles (n).
17.20.4 Memory Read Mode
⢠After the end of an auto-program, auto-erase, or status read operation, the command wait state
is entered. To read memory contents, a transition must be made to memory read mode by
means of a command write before the read is executed.
⢠Command writes can be performed in memory read mode, just as in the command wait state.
⢠Once memory read mode has been entered, consecutive reads can be performed.
⢠After power-on, memory read mode is entered.
Rev.7.00 Feb. 14, 2007 page 673 of 1108
REJ09B0089-0700
|
▷ |