English
Language : 

D12320VF25V Datasheet, PDF (226/1146 Pages) Renesas Technology Corp – Old Company Name in Catalogs and Other Documents
Section 7 Data Transfer Controller
Bit 7—DTC Software Activation Enable (SWDTE): Enables or disables DTC activation by
software.
Bit 7
SWDTE
0
1
Description
DTC software activation is disabled
(Initial value)
[Clearing conditions]
• When the DISEL bit is 0 and the specified number of transfers have not ended
• When 0 is written after a software activation data-transfer-complete interrupt is
issued to the CPU
DTC software activation is enabled
[Holding conditions]
• When the DISEL bit is 1 and data transfer has ended
• When the specified number of transfers have ended
• During data transfer due to software activation
Bits 6 to 0—DTC Software Activation Vectors 6 to 0 (DTVEC6 to DTVEC0): These bits
specify a vector number for DTC software activation.
The vector address is expressed as H'0400 + ((vector number) << 1). <<1 indicates a one-bit left-
shift. For example, when DTVEC6 to DTVEC0 = H'10, the vector address is H'0420.
7.2.9
Module Stop Control Register (MSTPCR)
MSTPCRH
MSTPCRL
Bit
: 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Initial value : 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1
R/W
: R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
MSTPCR is a 16-bit readable/writable register that performs module stop mode control.
When the MSTP14 bit in MSTPCR is set to 1, DTC operation stops at the end of the bus cycle and
a transition is made to module stop mode. However, 1 cannot be written in the MSTP14 bit while
the DTC is operating. For details, see section 19.5, Module Stop Mode.
MSTPCR is initialized to H'3FFF by a reset and in hardware standby mode. It is not initialized in
software standby mode.
Rev.7.00 Feb. 14, 2007 page 192 of 1108
REJ09B0089-0700