English
Language : 

D12320VF25V Datasheet, PDF (393/1146 Pages) Renesas Technology Corp – Old Company Name in Catalogs and Other Documents
Section 9 16-Bit Timer Pulse Unit (TPU)
Example of PWM Mode Setting Procedure: Figure 9.24 shows an example of the PWM mode
setting procedure.
PWM mode
Select counter clock
[1]
Select counter clearing source [2]
Select waveform output level [3]
Set TGR
[4]
Set PWM mode
[5]
Start count
[6]
[1] Select the counter clock with bits TPSC2 to
TPSC0 in TCR. At the same time, select the
input clock edge with bits CKEG1 and CKEG0 in
TCR.
[2] Use bits CCLR2 to CCLR0 in TCR to select the
TGR to be used as the TCNT clearing source.
[3] Use TIOR to designate the TGR as an output
compare register, and select the initial value and
output value.
[4] Set the period in the TGR selected in [2], and
set the duty in the other TGR.
[5] Select the PWM mode with bits MD3 to MD0 in
TMDR.
[6] Set the CST bit in TSTR to 1 to start the count
operation.
<PWM mode>
Figure 9.24 Example of PWM Mode Setting Procedure
Rev.7.00 Feb. 14, 2007 page 359 of 1108
REJ09B0089-0700