Section 12 Serial Communication Interface (SCI)
<Reception>
Read RDRF flag in SSR
RDRF = 1
No [1]
Yes
Read receive data in RDR
[1] Receive data being received
becomes invalid.
RE = 0
Transition to software
standby mode, etc.
[2]
Exit from software
standby mode, etc.
Change
No
operating mode?
Yes
Initialization
[2] Includes module stop mode.
RE = 1
<Start of reception>
Figure 12.26 Sample Flowchart for Mode Transition during Reception