82598EB Datasheet, PDF (502/596 Pages) Intel Corporation – Intel® 82598EB 10 Gigabit Ethernet Controller Datasheet
Intel® 82598EB 10 GbE Controller - NC-SI Support
21
Flex port 9 (OR)
22
Flex port 10 (OR)
23
Flex port 11 (OR)
24
Reserved
25
Reserved
26
Reserved
27
Reserved
28
Flex TCO 0 (OR)
29
Flex TCO 1 (OR)
30
Flex TCO 2 (OR)
31
Flex TCO 3 (OR)
If set, packets must also match the TCP/UDP port filter 9 or a different OR filter.
If set, packets must also match the TCP/UDP port filter 10 or a different OR filter.
If set, packets must also match the TCP/UDP port filter 11 or a different OR filter.
If set, packets must also match the Flex 128 TCO filter 0 or a different OR filter.
If set, packets must also match the Flex 128 TCO filter 1 or a different OR filter.
If set, packets must also match the Flex 128 TCO filter 2 or a different OR filter.
If set, packets must also match the Flex 128 TCO filter 3 or a different OR filter.
The filtering is divided into two decisions:
• Bits 0, 1, 2, 3, and 6 work in an AND manner; they all must be true in order for a packet to pass
(if any were set).
• Bits 5 and 7-31 work in an OR manner; at least one of them must be true for a packet to pass (if
any were set).
See Figure 5-5 for more details on the decision filters.
Note:
These filter settings operate according to the VLAN mode, as configured according to the
DMTF NC-SI specification. After disabling packet reduction filters, the MC must re-set the
VLAN mode using the Set VLAN command.
5.4.2.2.5.10 Set Intel Filters - Packet Addition Decision Filter Response (Intel Command
0x02, Filter Parameter 0x61)