Intel® 82598EB 10 GbE Controller - SMBus Pass-Through Transactions
Table 5-6. Management RCV Filter Parameters
Parameter
Filters Enables
Management-to-Host
Configuration
Fail-Over Configuration
Number
0x1
0xA
0xB
Flex Filter 0 Enable Mask and
Length
0x10
Flex Filter 0 Data
0x11
Flex Filter 1 Enable Mask and
Length
Flex Filter 1 Data
Flex Filter 2 Enable Mask and
Length
Flex Filter 2 Data
Flex Filter 3 Enable Mask and
Length
Flex Filter 3 Data
0x20
0x21
0x30
0x31
0x40
0x41
Parameter Data
Defines the generic filters configuration. The structure of this parameter is
four bytes as the MANC register.
Note: The general filter enable is in the Receive Enable command that
enables receive filtering.
This parameter defines which of the packet types identified as
manageability packets in the receive path are directed to the host
memory.
Data 5:2 = MNG2H register bits.
Fail-over register configuration.
The bytes of this parameter are loaded into the Fail-Over Configuration
register. See Section 5.3.11.3 for more information.
Data 2:5 = Fail-Over Configuration register (bit 0 of Data 2 is bit 0 of the
configuration register.).
Flex Filter 0 Mask.
Data 17:2 = Mask. Bit 0 in data 2 is the first bit of the mask.
Data 19:18 = Reserved. Should be set to 00b.
Date 20 = Flexible filter length.
Data 2 = Group of flex filter’s bytes:
0x0 = bytes 0-29
0x1 = bytes 30-59
0x2 = bytes 60-89
0x3 = bytes 90-119
0x4 = bytes 120-127
Data 3:32 = Flex filter data bytes. Data 3 is LSB.
Group's length is not a mandatory 30 bytes; it might vary according to
filter's length and must NOT be padded by zeros.
Note: Using this command to configure the filters data must be done after
the flex filter mask command is issued and the mask is set.
Same as parameter 0x10 but for filter 1.
Same as parameter 0x11 but for filter 1.
Same as parameter 0x10 but for filter 2.
Same as parameter 0x11 but for filter 2.
Same as parameter 0x10 but for filter 3.
Same as parameter 0x11 but for filter 3.