SH7014 Datasheet, PDF (447/754 Pages) Renesas Technology Corp – 32-Bit RISC Microcomputer
14. Mid-Speed A/D Converter ⎯ SH7016, SH7017 ⎯
Table 14.4 A/D Conversion Time (Single Mode)
CKS = 0
Notation Min Typ Max Min
A/D conversion start delay time t
D
10
⎯
Input sampling time
t
⎯
64
SPL
A/D conversion time
tCCNV
259
⎯
Note: Numbers in the table are in states (tcyc).
17
6
⎯
⎯
266
131
CKS = 1
Typ Max
⎯
9
32
⎯
⎯
134
14.4.4 MTU Trigger Input Timing
It is possible to start A/D conversion from an MTU trigger input. MTU trigger input is input from
MTU when the TRGE bit of the A/D control register (ADCR) is set to 1.
A/D conversion is started when the ADST bit of the A/D control/status register (ADCSR) is set to
1 by MTU trigger. Other operations, regardless of whether in the single or scan mode, are the
same as when setting the ADST bit to 1 with the software.
Figure 14.6 shows an example of external trigger input timing.
CK
MTU trigger
signal
ADST
A/D conversion
Figure 14.6 External Trigger Input Timing
Rev.5.00 Sep. 27, 2007 Page 413 of 716