10. Multifunction Timer Pulse Unit (MTU)
⢠Thirteen interrupt sources
⯠Channel 0 has four compare-match/input capture interrupts and one overflow interrupt
which can be requested independently.
⯠Channels 1 and 2 have two compare-match/input capture interrupts, one overflow interrupt,
and one underflow interrupt which can be requested independently.
⢠Automatic transfer of register data
⯠Block transfer, 1-word data transfers and 1-byte data transfers are possible through DMAC
activation.
⢠A/D converter conversion start trigger can be generated
⯠Channels 0 to 2 compare-match/input capture signals can be used as A/D converter
conversion start triggers.
Table 10.1 summarizes the MTU functions.
Rev.5.00 Sep. 27, 2007 Page 192 of 716