10. Multifunction Timer Pulse Unit (MTU)
TCNT value
H'0F07
H'09FB
H'0532
H'0000
TIOC0A
Time
TGRA
H'0532
H'0F07
H'09FB
TGRC
H'0532
H'0F07
Figure 10.20 Buffer Operation Example (Input Capture Register)
10.4.5 Cascade Connection Mode
Cascade connection mode is a function that connects the 16-bit counters of two channels together
to act as a 32-bit counter.
This function operates by using the TPSC2 to TPSC0 bits of the TCR register to set the channel 1
counter clock to count by TCNT2 counter overflow/underflow.
Note: When channel 1 is set to phase counting mode, the counter clock settings become
ineffective.
Table 10.6 shows the cascade connection combinations.
Table 10.6 Cascade Connection Combinations
Combination
Channel 1, channel 2
Upper 16 Bits
TCNT1
Lower 16 Bits
TCNT2
Rev.5.00 Sep. 27, 2007 Page 238 of 716