10. Multifunction Timer Pulse Unit (MTU)
(12) Operation when Error Occurs during PWM Mode 2 Operation, and Operation is
Restarted in Phase Counting Mode: Figure 10.71 shows an explanatory diagram of the case
where an error occurs in PWM mode 2 and operation is restarted in phase counting mode after re-
setting.
MTU output
TIOC*A
1
2
3
RESET TMDR TIOR
(PWM2) (1 init
0 out)
4
PFC
(MTU)
5
TSTR
(1)
6
Match
7
8
9
Error PFC TSTR
occurs (PORT) (0)
10
TMDR
(PCM)
11
TIOR
(1 init
0 out)
12
PFC
(MTU)
13
TSTR
(1)
• Not initialized (cycle register)
TIOC*B
Port output
PEn
Hi-Z
PEn
Hi-Z
Note: n = 0 to 15
Figure 10.71 Error Occurrence in PWM Mode 2, Recovery in Phase Counting Mode
1 to 9 are the same as in figure 10.68.
10. Set phase counting mode.
11. Initialize the pins with TIOR.
12. Set MTU output with the PFC.
13. Operation is restarted by TSTR.
Rev.5.00 Sep. 27, 2007 Page 286 of 716