English
Language : 

SH7014 Datasheet, PDF (315/754 Pages) Renesas Technology Corp – 32-Bit RISC Microcomputer
10. Multifunction Timer Pulse Unit (MTU)
(7) Operation when Error Occurs during PWM Mode 1 Operation, and Operation is
Restarted in PWM Mode 2: Figure 10.66 shows an explanatory diagram of the case where an
error occurs in PWM mode 1 and operation is restarted in PWM mode 2 after re-setting.
1
2
RESET TMDR
(PWM1)
MTU output
TIOC*A
3
TIOR
(1 init
0 out)
4
5
PFC TSTR
(MTU) (1)
6
7
8
9
10 11
Match Error PFC TSTR TMDR TIOR
occurs (PORT) (0) (PWM2) (1 init
0 out)
12
PFC
(MTU)
13
TSTR
(1)
• Not initialized (cycle register)
TIOC*B
• Not initialized (TIOC*B)
Port output
PEn
Hi-Z
PEn
Hi-Z
Note: n = 0 to 15
Figure 10.66 Error Occurrence in PWM Mode 1, Recovery in PWM Mode 2
1 to 9 are the same as in figure 10.64.
10. Set PWM mode 2.
11. Initialize the pins with TIOR. (In PWM mode 2, the cycle register pins are not initialized.)
12. Set MTU output with the PFC.
13. Operation is restarted by TSTR.
Rev.5.00 Sep. 27, 2007 Page 281 of 716
REJ09B0398-0500