English
Language : 

SH7014 Datasheet, PDF (321/754 Pages) Renesas Technology Corp – 32-Bit RISC Microcomputer
10. Multifunction Timer Pulse Unit (MTU)
(13) Operation when Error Occurs during Phase Counting Mode Operation, and Operation
is Restarted in Normal Mode: Figure 10.72 shows an explanatory diagram of the case where an
error occurs in phase counting mode and operation is restarted in normal mode after re-setting.
1
2
RESET TMDR
(PCM)
3
TIOR
(1 init
0 out)
4
PFC
(MTU)
5
TSTR
(1)
6
Match
7
8
9
10
11
Error PFC TSTR TMDR TIOR
occurs (PORT) (0) (normal) (1 init
0 out)
12
PFC
(MTU)
13
TSTR
(1)
MTU output
TIOC*A
TIOC*B
Port output
PEn
Hi-Z
PEn
Hi-Z
Note: n = 0 to 15
Figure 10.72 Error Occurrence in Phase Counting Mode, Recovery in Normal Mode
1. After a reset, MTU output is low and ports are in the high-impedance state.
2. Set phase counting mode.
3. Initialize the pins with TIOR. (The example shows initial high output, with low output on
compare-match occurrence.)
4. Set MTU output with the PFC.
5. The count operation is started by TSTR.
6. Output goes low on compare-match occurrence.
7. An error occurs.
8. Set port output with the PFC and output the inverse of the active level.
9. The count operation is stopped by TSTR.
10. Set in normal mode.
11. Initialize the pins with TIOR.
12. Set MTU output with the PFC.
13. Operation is restarted by TSTR.
Rev.5.00 Sep. 27, 2007 Page 287 of 716
REJ09B0398-0500