Operation when Error Occurs during Complementary PWM Mode Operation, and
Operation is Restarted in Reset-Synchronous PWM Mode: Figure 11.109 shows an
explanatory diagram of the case where an error occurs in complementary PWM mode and
operation is restarted in reset-synchronous PWM mode.
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17
RESET TOCR TMDR TOER PFC TSTR Match Error PFC TSTR TMDR TOER TOCR TMDR TOER PFC TSTR
(CPWM) (1) (MTU) (1)
occurs(PORT) (0) (normal) (0)
(RPWM) (1) (MTU) (1)
MTU module output
TIOC3A
TIOC3B
TIOC3D
Port output
PE8
PE9
High-Z
High-Z
PE11
High-Z
Figure 11.109 Error Occurrence in Complementary PWM Mode,
Recovery in Reset-Synchronous PWM Mode
1 to 10 are the same as in figure 11.105.
11. Set normal mode. (MTU output goes low.)
12. Disable channel 3 and 4 output with TOER.
13. Select the reset-synchronous PWM mode output level and cyclic output enabling/disabling
with TOCR.
14. Set reset-synchronous PWM.
15. Enable channel 3 and 4 output with TOER.
16. Set MTU output with the PFC.
17. Operation is restarted by TSTR.
Rev. 2.0, 09/02, page 333 of 732