15. A/D Converter
Bit 7⎯Trigger Enable (TRGE): Enables or disables starting of A/D conversion by an external
trigger or 8-bit timer compare match.
Bit 7
TRGE
0
1
Description
Starting of A/D conversion by an external trigger or 8-bit timer
compare match is disabled
A/D conversion is started at the falling edge of the external trigger
signal (ADTRG) or by an 8-bit timer compare match
(Initial value)
External trigger pin and 8-bit timer selection are performed by the 8-bit timer. For details, see
section 10, 8-Bit Timers.
Bits 6 to 1⎯Reserved: These bits cannot be modified and are always read as 1.
Bit 0⎯Reserved: This bit can be read or written, but should not be set to 1.