HD6413007F20 Datasheet, PDF (456/798 Pages) Renesas Technology Corp – Hardware Manual Renesas 16-Bit Single-Chip Microcomputer H8 Family/H8/300H Series | |||
|
◁ |
13. Serial Communication Interface
Synchronous mode
Serial data communication is synchronized with a clock signal. The SCI can communicate with
other chips having a synchronous communication function.
There is a single serial data communication format.
⯠Data length:
8 bits
⯠Receive error detection: overrun errors
⢠Full-duplex communication
The transmitting and receiving sections are independent, so the SCI can transmit and receive
simultaneously. The transmitting and receiving sections are both double-buffered, so serial
data can be transmitted and received continuously.
⢠The following settings can be made for the serial data to be transferred:
⯠LSB-first or MSB-first transfer
⯠Inversion of data logic level
⢠Built-in baud rate generator with selectable bit rates
⢠Selectable transmit/receive clock sources: internal clock from baud rate generator, or external
clock from the SCK pin
⢠Four types of interrupts
Transmit-data-empty, transmit-end, receive-data-full, and receive-error interrupts are requested
independently. The transmit-data-empty and receive-data-full interrupts from SCI0 can
activate the DMA controller (DMAC) to transfer data.
Features of the smart card interface are listed below.
⢠Asynchronous communication
⯠Data length: 8 bits
⯠Parity bits generated and checked
⯠Error signal output in receive mode (parity error)
⯠Error signal detect and automatic data retransmit in transmit mode
⯠Supports both direct convention and inverse convention
⢠Built-in baud rate generator with selectable bit rates
⢠Three types of interrupts
Transmit-data-empty, receive-data-full, and transmit/receive-error interrupts are requested
independently. The transmit-data-empty and receive-data-full interrupts can activate the DMA
controller (DMAC) to transfer data.
Rev.5.00 Sep. 12, 2007 Page 426 of 764
REJ09B0396-0500
|
▷ |