Section 11 Serial Communication Interface
Bit 3—Parity Error (PER): Indicates that data reception ended abnormally due to a parity error
in asynchronous mode.
Bit 3
PER
Description
0
Receiving is in progress or has ended normally*1
(Initial value)
[Clearing condition]
The chip is reset or enters standby mode. Software reads PER while it is set to 1, then
writes 0
1
A receive parity error occurred*2
[Setting condition]
The number of 1s in receive data, including the parity bit, does not match the even or
odd parity setting of O/E in SMR
Notes: 1. Clearing the RE bit to 0 in SCR does not affect the PER flag, which retains its previous
value.
2. When a parity error occurs the SCI transfers the receive data into RDR but does not set
the RDRF flag. Serial receiving cannot continue while the PER flag is set to 1. In
synchronous mode, serial transmitting is also disabled.
Bit 2—Transmit End (TEND): Indicates that when the last bit of a serial character was
transmitted TDR did not contain new transmit data, so transmission has ended. The TEND flag is
a read-only bit and cannot be written.
Bit 2
TEND
0
1
Description
Transmission is in progress
[Clearing condition]
Software reads TDRE while it is set to 1, then writes 0 in the TDRE flag
End of transmission
(Initial value)
[Setting conditions]
• The chip is reset or enters standby mode. The TE bit is cleared to 0 in SCR
• TDRE is 1 when the last bit of a serial character is transmitted
Rev.3.00 Mar. 26, 2007 Page 348 of 682
REJ09B0353-0300