English
Language : 

HD6432633 Datasheet, PDF (963/1453 Pages) Renesas Technology Corp – Series of Microcomputers (MCUs: microcomputer units)
Bit 4—Program Setup Bit 1 (PSU1): Prepares for a transition to program mode. Set this bit to 1
before setting the P1 bit in FLMCR1 to 1. Do not set the SWE1, ESU1, EV1, PV1, E1, or P1 bit
at the same time.
Bit 4
PSU1
0
1
Description
Program setup cleared
Program setup
[Setting condition]
When FWE = 1 and SWE1 = 1
(Initial value)
Bit 3—Erase-Verify 1 (EV1): Selects erase-verify mode transition or clearing. Do not set the
SWE1, ESU1, PSU1, PV1, E1, or P1 bit at the same time.
Bit 3
EV1
0
1
Description
Erase-verify mode cleared
Transition to erase-verify mode
[Setting condition]
When FWE = 1 and SWE1 = 1
(Initial value)
Bit 2—Program-Verify 1 (PV1): Selects program-verify mode transition or clearing. Do not set
the SWE1, ESU1, PSU1, EV1, E1, or P1 bit at the same time.
Bit 2
PV1
0
1
Description
Program-verify mode cleared
Transition to program-verify mode
[Setting condition]
When FWE = 1 and SWE1 = 1
(Initial value)
909