12.3.6 Pulse Output Triggered by Input Capture
Pulse output can be triggered by TPU input capture as well as by compare match. If TGRA
functions as an input capture register in the TPU channel selected by PCR, pulse output will be
triggered by the input capture signal.
Figure 12-9 shows the timing of this output.
ø
TIOC pin
Input capture
signal
NDR
PODR
PO
N
M
N
M
N
Figure 12-9 Pulse Output Triggered by Input Capture (Example)