English
Language : 

HD6432633 Datasheet, PDF (944/1453 Pages) Renesas Technology Corp – Series of Microcomputers (MCUs: microcomputer units)
20.3 Operation
The D/A converter module has two built-in D/A converter circuits that can operate independently.
D/A conversion is performed continuously whenever enabled by the D/A control register (DACR).
When a new value is written in DADR0 or DADR1, conversion of the new value begins
immediately. The converted result is output by setting the DAOE0 or DAOE1 bit to 1.
An example of conversion on channel 0 is given next. Figure 20-2 shows the timing.
• Software writes the data to be converted in DADR0.
• D/A conversion begins when the DAOE0 bit in DACR is set to 1. After the elapse of the
conversion time, analog output appears at the DA0 pin. The output value is Vref × (DADR0
value)/256.
This output continues until a new value is written in DADR0 or the DAOE0 bit is cleared to 0.
• If a new value is written in DADR0, conversion begins immediately. Output of the converted
result begins after the conversion time.
• When the DAOE0 bit is cleared to 0, DA0 becomes an input pin.
DADR0
write cycle
DACR
write cycle
DADR0
write cycle
DACR
write cycle
Ø
Address
DADR0
Conversion data (1)
Conversion data (2)
DAOE0
DA0
High-impedance state
Conversion result (1)
t DCONV
Conversion result (2)
t DCONV
t DCONV: D/A conversion time
Figure 20-2 D/A Conversion (Example)
890