English
Language : 

HD6432633 Datasheet, PDF (646/1453 Pages) Renesas Technology Corp – Series of Microcomputers (MCUs: microcomputer units)
11.7 Usage Notes
Note that the kinds of operation and contention described below occur during TPU operation.
Input Clock Restrictions: The input clock pulse width must be at least 1.5 states in the case of
single-edge detection, and at least 2.5 states in the case of both-edge detection. The TPU will not
operate properly with a narrower pulse width.
In phase counting mode, the phase difference and overlap between the two input clocks must be at
least 1.5 states, and the pulse width must be at least 2.5 states. Figure 11-48 shows the input clock
conditions in phase counting mode.
TCLKA
(TCLKC)
TCLKB
(TCLKD)
Phase
Phase
differ-
differ-
Overlap ence Overlap ence
Pulse width
Pulse width
Pulse width
Pulse width
Notes: Phase difference and overlap: 1.5 states or more
Pulse width
: 2.5 states or more
Figure 11-48 Phase Difference, Overlap, and Pulse Width in Phase Counting Mode
Caution on Period Setting: When counter clearing by compare match is set, TCNT is cleared in
the final state in which it matches the TGR value (the point at which the count value matched by
TCNT is updated). Consequently, the actual counter frequency is given by the following formula:
f= ø
(N + 1)
Where
f : Counter frequency
ø : Operating frequency
N : TGR set value