English
Language : 

HD6432633 Datasheet, PDF (263/1453 Pages) Renesas Technology Corp – Series of Microcomputers (MCUs: microcomputer units)
When RCTS is set to 1, the CAS signal timing differs when reading and writing, being asserted Ω
cycle earlier when reading.
Tp
ø
A23 to A0
AS
CSn (RAS)
CAS, LCAS
Read
HWR (WE)
RD
Tr
Tc1
Tc2
row
column
RCTS= 0
RCTS= 1
D15 toD0
CAS, LCAS
Write
HWR (WE)
RD
D15 to D0
Note: n=2 to 5
Figure 7-15 Basic Access Timing