English
Language : 

HD6432633 Datasheet, PDF (1098/1453 Pages) Renesas Technology Corp – Series of Microcomputers (MCUs: microcomputer units)
Table 25-10 I2C Bus Timing
Conditions: VCC = PLLVCC = 3.0 V to 3.6 V, PVCC = 3.0 V to 5.5 V, VSS = AVSS = PLLVSS = 0 V,
ø = 5 MHz to maximum operating frequency, Ta = –20°C to +75°C (regular
specifications), Ta = –40°C to +85°C (wide-range specifications)
Ratings
Item
Symbol Min
Typ Max Unit Notes
SCL input cycle time
SCL input high pulse width
SCL input low pulse width
SCL, SDA input rise time
SCL, SDA input fall time
SCL, SDA input spike pulse
elimination time
t SCL
t SCLH
t SCLL
t Sr
t Sf
t SP
12tcyc
3t cyc
5t cyc
—
—
—
—
—
ns Figure 25-33
—
—
ns
—
—
ns
—
7.5tcyc* ns
—
300 ns
—
1t cyc
ns
SDA input bus free time
t BUF
5t cyc
Start condition input hold time
t STAH
3t cyc
Retransmission start condition input tSTAS
3t cyc
setup time
—
—
ns
—
—
ns
—
—
ns
Stop condition input setup time
t STOS
3t cyc
—
—
ns
Data input setup time
t SDAS
0.5tcyc
—
—
ns
Data input hold time
t SDAH
0
—
—
ns
SCL, SDA capacitive load
Cb
—
—
400 pF
Note: * 17.5tcyc can be set according to the clock selected for use by the I2C module. For details,
see section 18.4, Usage Notes.
1044