11.4.3 Synchronous Operation
In synchronous operation, the values in a number of TCNT counters can be rewritten
simultaneously (synchronous presetting). Also, a number of TCNT counters can be cleared
simultaneously by making the appropriate setting in TCR (synchronous clearing).
Synchronous operation enables TGR to be incremented with respect to a single time base.
Channels 0 to 5 can all be designated for synchronous operation.
Example of Synchronous Operation Setting Procedure: Figure 11-14 shows an example of the
synchronous operation setting procedure.
Synchronous operation
selection
Set synchronous
operation
[1]
Synchronous presetting
Set TCNT
[2]
Synchronous clearing
Clearing
source generation
channel?
Yes
Select counter
clearing source
No
[3]
Start count
[5]
Set synchronous
counter clearing
[4]
Start count
[5]
<Synchronous presetting>
<Counter clearing>
<Synchronous clearing>
[1] Set to 1 the SYNC bits in TSYR corresponding to the channels to be designated for synchronous
operation.
[2] When the TCNT counter of any of the channels designated for synchronous operation is
written to, the same value is simultaneously written to the other TCNT counters.
[3] Use bits CCLR2 to CCLR0 in TCR to specify TCNT clearing by input capture/output compare,
etc.
[4] Use bits CCLR2 to CCLR0 in TCR to designate synchronous clearing for the counter clearing
source.
[5] Set to 1 the CST bits in TSTR for the relevant channels, to start the count operation.
Figure 11-14 Example of Synchronous Operation Setting Procedure
561