English
Language : 

HD6432633 Datasheet, PDF (1026/1453 Pages) Renesas Technology Corp – Series of Microcomputers (MCUs: microcomputer units)
23B.1.2 Register Configuration
The clock pulse generator is controlled by SCKCR and LPWRCR. Table 23B-1 shows the register
configuration.
Table 23B-1 Clock Pulse Generator Register
Name
Abbreviation R/W
System clock control register
SCKCR
R/W
Low-power control register
LPWRCR
R/W
Note:* Lower 16 bits of the address.
Initial Value
H'00
H'00
Address*
H'FDE6
H'FDEC
23B.2 Register Descriptions
23B.2.1 System Clock Control Register (SCKCR)
Bit
:
7
6
5
4
3
2
1
0
PSTOP —
—
— STCS SCK2 SCK1 SCK0
Initial value:
0
0
0
0
0
0
0
0
R/W
: R/W
—
—
—
R/W R/W R/W R/W
SCKCR is an 8-bit readable/writable register that performs ø clock output control, selection of
operation when the PLL circuit frequency multiplication factor is changed, and medium-speed
mode control.
SCKCR is initialized to H'00 by a reset and in hardware standby mode. It is not initialized in
software standby mode.
Bit 7—ø Clock Output Disable (PSTOP): Controls ø output.
Description
Bit 7
PSTOP
High-Speed Mode,
Medium-Speed Mode, Sleep Mode
Sub-Active Mode
Sub-Sleep Mode
Software
Standby Mode,
Watch Mode*,
Hardware
Direct Transitions* Standby Mode
0
ø output (initial value) ø output
Fixed high
High impedance
1
Fixed high
Fixed high
Fixed high
High impedance
Note: * This function is not available in the H8S/2695.
Bits 6 to 4—Reserved: These bits are always read as 0 and cannot be modified.
972