Table A.1 Address List (cont)
Area 7
Power-On Manual
Module Register P4 Address Address*1 Size Reset
Reset
Synchro-
nization
Sleep Standby Clock
H-UDI SDIR
H'FFF0 0000 H'1FF0 0000 16 H'FFFF*2 Held
Held Held Pclk
H-UDI SDDR H'FFF0 0008 H'1FF0 0008 32 Undefined Held
Held Held Pclk
H-UDI SDINT*5 H'FFF0 0014 H'1FF0 0014 16 H'0000
Held
Held Held Pclk
Notes: *1 With control registers, the above addresses in the physical page number field can be
accessed by means of a TLB setting. When these addresses are referenced directly
without using the TLB, operations are limited.
*2 Includes undefined bits. See the descriptions of the individual modules.
*3 Use word-size access when writing. Perform the write with the upper byte set to H'5A or
H'A5, respectively. Byte- and longword-size writes cannot be used.
Use byte-size access when reading.
*4 SH7750S, SH7750R only
*5 SH7750R only
*6 Includes power-down states