|
HD6417750 Datasheet, PDF (724/1039 Pages) Renesas Technology Corp – SuperH RISC engine | |||
|
◁ |
Bit 3âFraming Error (FER): Indicates whether or not a framing error has been found in the
data that is to be read next from SCFRDR2.
Bit 3: FER
0
Description
There is no framing error that is to be read from SCFRDR2 (Initial value)
[Clearing conditions]
⢠Power-on reset or manual reset
⢠When there is no framing error in the data that is to be read next from
SCFRDR2
1
There is a framing error that is to be read from SCFRDR2
[Setting condition]
When there is a framing error in the data that is to be read next from
SCFRDR2
Bit 2âParity Error (PER): Indicates whether or not a parity error has been found in the data that
is to be read next from SCFRDR2.
Bit 2: PER
0
Description
There is no parity error that is to be read from SCFRDR2
(Initial value)
[Clearing conditions]
⢠Power-on reset or manual reset
⢠When there is no parity error in the data that is to be read next from
SCFRDR2
1
There is a parity error in the receive data that is to be read from SCFRDR2
[Setting condition]
When there is a parity error in the data that is to be read next from
SCFRDR2
Rev. 6.0, 07/02, page 672 of 986
|
▷ |