SAM4L Datasheet, PDF (625/1185 Pages) ATMEL Corporation – ATSAM ARM-based Flash MCU | |||
|
◁ |
ATSAM4L4/L2
24.7.6 Channel Status Register
Name:
CSR
Access Type:
Read-only
Offset:
0x14
Reset Value:
0x00000000
31
LINHTE
30
LINSTE
29
LINSNRE
28
LINCE
27
LINIPE
26
LINISFE
25
LINBE
24
MANERR
23
CTS/LINBLS
22
DCD
21
DSR
20
19
18
17
16
RI
CTSIC
DCDIC
DSRIC
RIIC
15
LINTC
14
LINID
13
NACK/LINBK
12
RXBUFF
11
10
9
8
â
ITER/UNRE TXEMPTY
TIMEOUT
7
6
5
4
PARE
FRAME
OVRE
â
3
2
1
0
â
RXBRK
TXRDY
RXRDY
⢠LINHTE: LIN Header Time-out Error
0: No LIN Header Time-out Error has been detected since the last RSTSTA.
1: A LIN Header Time-out Error has been detected since the last RSTSTA.
This bit is cleared by writing a one to CR.RSTSTA.
⢠LINSTE: LIN Sync Tolerance Error
0: No LIN Sync Tolerance Error has been detected since the last RSTSTA.
1: A LIN Sync Tolerance Error has been detected since the last RSTSTA.
This bit is cleared by writing a one to CR.RSTSTA.
⢠LINSNRE: LIN Slave Not Responding Error
0: No LIN Slave Not Responding Error has been detected since the last RSTSTA.
1: A LIN Slave Not Responding Error has been detected since the last RSTSTA.
This bit is cleared by writing a one to CR.RSTSTA.
⢠LINCE: LIN Checksum Error
0: No LIN Checksum Error has been detected since the last RSTSTA.
1: A LIN Checksum Error has been detected since the last RSTSTA.
This bit is cleared by writing a one to CR.RSTSTA.
⢠LINIPE: LIN Identifier Parity Error
0: No LIN Identifier Parity Error has been detected since the last RSTSTA.
1: A LIN Identifier Parity Error has been detected since the last RSTSTA.
This bit is cleared by writing a one to CR.RSTSTA.
⢠LINISFE: LIN Inconsistent Sync Field Error
0: No LIN Inconsistent Sync Field Error has been detected since the last RSTSTA
1: The USART is configured as a Slave node and a LIN Inconsistent Sync Field Error has been detected since the last RSTSTA.
This bit is cleared by writing a one to CR.RSTSTA.
⢠LINBE: LIN Bit Error
0: No Bit Error has been detected since the last RSTSTA.
1: A Bit Error has been detected since the last RSTSTA.
This bit is cleared by writing a one to CR.RSTSTA.
⢠MANERR: Manchester Error
0: No Manchester error has been detected since the last RSTSTA.
1: At least one Manchester error has been detected since the last RSTSTA.
42023CâSAMâ02/2013