English
Language : 

SAM4L Datasheet, PDF (182/1185 Pages) ATMEL Corporation – ATSAM ARM-based Flash MCU
12.7.13 BOD Level Register
Name:
BOD18/33LEVEL
Access Type:
Read/Write
Reset Value:
0x00000000
ATSAM4L4/L2
31
30
29
28
27
26
25
24
RANGE
-
-
-
-
-
-
23
22
21
20
19
18
17
16
-
-
-
-
-
-
-
-
15
14
13
12
11
10
9
8
-
-
-
-
-
-
-
-
7
6
5
4
3
2
1
0
-
-
VAL[5:0]
• RANGE: BOD Threshold Range (available for BOD18 only)
0: The Standard Threshold Range is selected. See Section 42.8 ”Analog Characteristics” on page 1133 for actual voltage levels.
1: The Low Threshold Range is selected. See Section 42.8 ”Analog Characteristics” on page 1133 for actual voltage levels.
Note that any change to the RANGE field of the BOD18LEVEL register should be done with the BOD18 deactivated, this is to
avoid spurious resets or interrupts.
• VAL: BOD Value
This field sets the triggering voltage threshold for the BOD. See Section 42.8 ”Analog Characteristics” on page 1133 for actual
voltage levels.
Note that any change to the VAL field of the BOD18/33LEVEL register should be done with the BOD deactivated, this is to avoid
spurious resets or interrupts.
42023C–SAM–02/2013