Section 12 Serial Communication Interface (SCI)
Initial
Bit Bit Name Value R/W
Description
5
ORER
0
R/(W)* Overrun Error
[Setting condition]
• When the next serial reception is completed while
RDRF = 1
[Clearing conditions]
• Power-on reset or software standby mode
• When 0 is written to ORER after reading ORER = 1
4
FER
0
R/(W)*
The ORER flag is not affected and retains their previous
values when the RE bit in SCR is cleared to 0.
Framing Error
[Setting condition]
• When the stop bit is 0
[Clearing conditions]
• Power-on reset or software standby mode
• When 0 is written to FER after reading FER = 1
In 2-stop-bit mode, only the first stop bit is checked.
3
PER
0
R/(W)*
The FER flag is not affected and retains their previous
values when the RE bit in SCR is cleared to 0.
Parity Error
[Setting condition]
• When a parity error is detected during reception
[Clearing conditions]
• Power-on reset or software standby mode
• When 0 is written to PER after reading PER = 1
The PER flag is not affected and retains their previous
values when the RE bit in SCR is cleared to 0.
Rev. 4.00 Dec 05, 2005 page 325 of 564
REJ09B0270-0400