English
Language : 

SH7046 Datasheet, PDF (326/611 Pages) Renesas Technology Corp – Renesas 32-Bit RISC Microcomputer SuperH RISC engine Family/SH7046 Series
Section 10 Multi-Function Timer Pulse Unit (MTU)
(19) Operation when Error Occurs during Phase Counting Mode Operation, and Operation
is Restarted in PWM Mode 2: Figure 10.103 shows an explanatory diagram of the case where an
error occurs in phase counting mode and operation is restarted in PWM mode 2 after re-setting.
MTU module
output
TIOC*A
1
2
RESET TMDR
(PCM)
3
TIOR
(1 init
0 out)
4
PFC
(MTU)
5
TSTR
(1)
6
Match
7
8
9
10 11
Error PFC TSTR TMDR TIOR
occurs (PORT) (0) (PWM2) (1 init
0 out)
12
PFC
(MTU)
13
TSTR
(1)
• Not initialized (cycle register)
TIOC*B
Port output
PEn
High-Z
PEn
High-Z
n=0 to 15
Figure 10.103 Error Occurrence in Phase Counting Mode, Recovery in PWM Mode 2
1 to 9 are the same as in Figure 10.101.
10. Set PWM mode 2.
11. Initialize the pins with TIOR. (In PWM mode 2, the cycle register pins are not initialized.)
12. Set MTU output with the PFC.
13. Operation is restarted by TSTR.
Rev. 4.00 Dec 05, 2005 page 282 of 564
REJ09B0270-0400