English
Language : 

SH7046 Datasheet, PDF (319/611 Pages) Renesas Technology Corp – Renesas 32-Bit RISC Microcomputer SuperH RISC engine Family/SH7046 Series
Section 10 Multi-Function Timer Pulse Unit (MTU)
(12) Operation when Error Occurs during PWM Mode 1 Operation, and Operation is
Restarted in Reset-Synchronous PWM Mode: Figure 10.96 shows an explanatory diagram of
the case where an error occurs in PWM mode 1 and operation is restarted in reset-synchronous
PWM mode after re-setting.
MTU module
output
TIOC3A
1
2
3
4
RESET TMDR TOER TIOR
(PWM1) (1) (1 init
0 out)
5
6
PFC TSTR
(MTU) (1)
7
Match
8
9
10
11
12
13
14
Error PFC TSTR TMDR TIOR TIOR TOER
occurs (PORT) (0) (normal) (0 init (disabled) (0)
0 out)
15
16
17
TOCR TMDR TOER
(RPWM) (1)
18
PFC
(MTU)
19
TSTR
(1)
TIOC3B
• Not initialized (TIOC3B)
TIOC3D
• Not initialized (TIOC3D)
Port output
PE8
PE9
High-Z
High-Z
PE11
High-Z
Figure 10.96 Error Occurrence in PWM Mode 1, Recovery in Reset-Synchronous
PWM Mode
1 to 14 are the same as in Figure 10.95.
15. Select the reset-synchronous PWM output level and cyclic output enabling/disabling with
TOCR.
16. Set reset-synchronous PWM.
17. Enable channel 3 and 4 output with TOER.
18. Set MTU output with the PFC.
19. Operation is restarted by TSTR.
Rev. 4.00 Dec 05, 2005 page 275 of 564
REJ09B0270-0400