Section 10 Multi-Function Timer Pulse Unit (MTU)
(28) Operation when Error Occurs during Reset-Synchronous PWM Mode Operation, and
Operation is Restarted in Complementary PWM Mode: Figure 10.112 shows an explanatory
diagram of the case where an error occurs in reset-synchronous PWM mode and operation is
restarted in complementary PWM mode after re-setting.
1
2
3
4
5
6
7
8
9
10 11
12
13
14
15
16
RESET TOCR TMDR TOER PFC TSTR Match Error PFC TSTR TOER TOCR TMDR TOER PFC TSTR
(RPWM) (1) (MTU) (1)
occurs (PORT) (0) (0)
(CPWM) (1) (MTU) (1)
MTU module
output
TIOC3A
TIOC3B
TIOC3D
Port output
PE8
PE9
High-Z
High-Z
PE11
High-Z
Figure 10.112 Error Occurrence in Reset-Synchronous PWM Mode,
Recovery in Complementary PWM Mode
1 to 10 are the same as in Figure 10.110.
11. Disable channel 3 and 4 output with TOER.
12. Select the complementary PWM output level and cyclic output enabling/disabling with
TOCR.
13. Set complementary PWM. (The MTU cyclic output pin goes low.)
14. Enable channel 3 and 4 output with TOER.
15. Set MTU output with the PFC.
16. Operation is restarted by TSTR.
Rev. 4.00 Dec 05, 2005 page 291 of 564