Section 10 Multi-Function Timer Pulse Unit (MTU)
(18) Operation when Error Occurs during Phase Counting Mode Operation, and Operation
is Restarted in PWM Mode 1: Figure 10.102 shows an explanatory diagram of the case where an
error occurs in phase counting mode and operation is restarted in PWM mode 1 after re-setting.
MTU module
output
TIOC*A
1
2
RESET TMDR
(PCM)
3
TIOR
(1 init
0 out)
4
PFC
(MTU)
5
TSTR
(1)
6
Match
7
8
9
10 11
Error PFC TSTR TMDR TIOR
occurs (PORT) (0) (PWM1) (1 init
0 out)
12
PFC
(MTU)
13
TSTR
(1)
TIOC*B
• Not initialized (TIOC*B)
Port output
PEn
High-Z
PEn
High-Z
n=0 to 15
Figure 10.102 Error Occurrence in Phase Counting Mode, Recovery in PWM Mode 1
1 to 9 are the same as in Figure 10.101.
10. Set PWM mode 1.
11. Initialize the pins with TIOR. (In PWM mode 1, the TIOC *B side is not initialized.)
12. Set MTU output with the PFC.
13. Operation is restarted by TSTR.
Rev. 4.00 Dec 05, 2005 page 281 of 564
REJ09B0270-0400