Section 10 Multi-Function Timer Pulse Unit (MTU)
Example of Synchronous Operation: Figure 10.12 shows an example of synchronous operation.
In this example, synchronous operation and PWM mode 1 have been designated for channels 0 to
2, TGRB_0 compare match has been set as the channel 0 counter clearing source, and
synchronous clearing has been set for the channel 1 and 2 counter clearing source.
Three-phase PWM waveforms are output from pins TIOC0A, TIOC1A, and TIOC2A. At this
time, synchronous presetting, and synchronous clearing by TGRB_0 compare match, are
performed for channel 0 to 2 TCNT counters, and the data set in TGRB_0 is used as the PWM
cycle.
For details of PWM modes, see section 10.4.5, PWM Modes.
TCNT0 to TCNT2
values
TGRB_0
TGRB_1
TGRA_0
TGRB_2
TGRA_1
TGRA_2
H'0000
Synchronous clearing by TGRB_0 compare match
TIOCA_0
TIOCA_1
TIOCA_2
Figure 10.12 Example of Synchronous Operation
Time
10.4.3 Buffer Operation
Buffer operation, provided for channels 0, 3, and 4, enables TGRC and TGRD to be used as buffer
registers.
Buffer operation differs depending on whether TGR has been designated as an input capture
register or as a compare match register.
Table 10.29 shows the register combinations used in buffer operation.