SH7046 Datasheet, PDF (252/611 Pages) Renesas Technology Corp – Renesas 32-Bit RISC Microcomputer SuperH RISC engine Family/SH7046 Series
Section 10 Multi-Function Timer Pulse Unit (MTU)
Table 10.40 Register Settings for Complementary PWM Mode
Channel Counter/Register Description
Read/Write from CPU
3
TCNT_3
Start of up-count from value set
in dead time register
Maskable by BSC/BCR1
setting*
TGRA_3
Set TCNT_3 upper limit value
(1/2 carrier cycle + dead time)
Maskable by BSC/BCR1
setting*
TGRB_3
PWM output 1 compare register
Maskable by BSC/BCR1
setting*
TGRC_3
TGRA_3 buffer register
Always readable/writable
TGRD_3
PWM output 1/TGRB_3 buffer
register
Always readable/writable
4
TCNT_4
Up-count start, initialized to
H'0000
Maskable by BSC/BCR1
setting*
TGRA_4
PWM output 2 compare register
Maskable by BSC/BCR1
setting*
TGRB_4
PWM output 3 compare register
Maskable by BSC/BCR1
setting*
TGRC_4
PWM output 2/TGRA_4 buffer
register
Always readable/writable
TGRD_4
PWM output 3/TGRB_4 buffer
register
Always readable/writable
Timer dead time data register
(TDDR)
Set TCNT_4 and TCNT_3 offset Maskable by BSC/BCR1
value (dead time value)
setting*
Timer cycle data register
(TCDR)
Set TCNT_4 upper limit value
(1/2 carrier cycle)
Maskable by BSC/BCR1
setting*
Timer cycle buffer register
(TCBR)
TCDR buffer register
Always readable/writable
Subcounter (TCNTS)
Subcounter for dead time
generation
Read-only
Temporary register 1 (TEMP1) PWM output 1/TGRB_3
temporary register
Not readable/writable
Temporary register 2 (TEMP2) PWM output 2/TGRA_4
temporary register
Not readable/writable
Temporary register 3 (TEMP3) PWM output 3/TGRB_4
temporary register
Not readable/writable
Note: * Access can be enabled or disabled according to the setting of bit 13 (MTURWE) in
BSC/BCR1 (bus controller/bus control register 1).
Rev. 4.00 Dec 05, 2005 page 208 of 564
REJ09B0270-0400