Section 10 Multi-Function Timer Pulse Unit (MTU)
(3) Operation when Error Occurs during Normal Mode Operation, and Operation is
Restarted in PWM Mode 2: Figure 10.87 shows an explanatory diagram of the case where an
error occurs in normal mode and operation is restarted in PWM mode 2 after re-setting.
MTU module
output
TIOC*A
1
2
3
RESET TMDR TOER
(normal) (1)
4
TIOR
(1 init
0 out)
5
6
PFC TSTR
(MTU) (1)
7
Match
8
9
10 11 12
Error PFC TSTR TMDR TIOR
occurs (PORT) (0) (PWM2) (1 init
0 out)
13
PFC
(MTU)
14
TSTR
(1)
• Not initialized (cycle register)
TIOC*B
Port output
PEn
High-Z
PEn
High-Z
n=0 to 15
Figure 10.87 Error Occurrence in Normal Mode, Recovery in PWM Mode 2
1 to 10 are the same as in Figure 10.85.
11. Set PWM mode 2.
12. Initialize the pins with TIOR. (In PWM mode 2, the cycle register pins are not initialized. If
initialization is required, initialize in normal mode, then switch to PWM mode 2.)
13. Set MTU output with the PFC.
14. Operation is restarted by TSTR.
Note: PWM mode 2 can only be set for channels 0–2, and therefore TOER setting is not
necessary.
Rev. 4.00 Dec 05, 2005 page 266 of 564
REJ09B0270-0400