English
Language : 

SH7046 Datasheet, PDF (313/611 Pages) Renesas Technology Corp – Renesas 32-Bit RISC Microcomputer SuperH RISC engine Family/SH7046 Series
Section 10 Multi-Function Timer Pulse Unit (MTU)
(6) Operation when Error Occurs during Normal Mode Operation, and Operation is
Restarted in Reset-Synchronous PWM Mode: Figure 10.90 shows an explanatory diagram of
the case where an error occurs in normal mode and operation is restarted in reset-synchronous
PWM mode after re-setting.
MTU module
output
TIOC3A
1
2
3
4
RESET TMDR TOER TIOR
(normal) (1) (1 init
0 out)
5
PFC
(MTU)
6
TSTR
(1)
7
8
9
10
Match Error PFC TSTR
occurs (PORT) (0)
11
12
13
14
15
16
17
TIOR TIOR TOER TOCR TMDR TOER PFC
(0 init (disabled) (0)
(CPWM) (1) (MTU)
0 out)
18
TSTR
(1)
TIOC3B
TIOC3D
Port output
PE8
PE9
High-Z
High-Z
PE11
High-Z
Figure 10.90 Error Occurrence in Normal Mode, Recovery in Reset-Synchronous
PWM Mode
1 to 13 are the same as in Figure 10.89.
14. Select the reset-synchronous PWM output level and cyclic output enabling/disabling with
TOCR.
15. Set reset-synchronous PWM.
16. Enable channel 3 and 4 output with TOER.
17. Set MTU output with the PFC.
18. Operation is restarted by TSTR.
Rev. 4.00 Dec 05, 2005 page 269 of 564
REJ09B0270-0400