English
Language : 

MC9S12G Datasheet, PDF (492/1160 Pages) Freescale Semiconductor, Inc – Ignores external trigger. Performs one conversion sequence and stops.
Freescale’s Scalable Controller Area Network (S12MSCANV3)
Table 16-9. Time Segment 2 Values
TSEG22
TSEG21
TSEG20
Time Segment 2
0
0
0
1 Tq clock cycle1
0
0
1
2 Tq clock cycles
:
:
:
:
1
1
0
7 Tq clock cycles
1
1
1
8 Tq clock cycles
1 This setting is not valid. Please refer to Table 16-37 for valid settings.
Table 16-10. Time Segment 1 Values
TSEG13
TSEG12
TSEG11
TSEG10
Time segment 1
0
0
0
0
1 Tq clock cycle1
0
0
0
1
2 Tq clock cycles1
0
0
1
0
3 Tq clock cycles1
0
0
1
1
4 Tq clock cycles
:
:
:
:
:
1
1
1
0
15 Tq clock cycles
1
1
1
1
16 Tq clock cycles
1 This setting is not valid. Please refer to Table 16-37 for valid settings.
The bit time is determined by the oscillator frequency, the baud rate prescaler, and the number of time
quanta (Tq) clock cycles per bit (as shown in Table 16-9 and Table 16-10).
Eqn. 16-1
Bit Time= (---P----r---e---f-s-C--c---A-a----Nl--e--C-r----L--v--K-a----l--u----e----) • (1 + TimeSegment1 + TimeSegment2)
16.3.2.5 MSCAN Receiver Flag Register (CANRFLG)
A flag can be cleared only by software (writing a 1 to the corresponding bit position) when the condition
which caused the setting is no longer valid. Every flag has an associated interrupt enable bit in the
CANRIER register.
MC9S12G Family Reference Manual, Rev.1.01
492
Freescale Semiconductor
This document is valid for the S12G96 and the S12G128 device. All information related to other devices is preliminary.