SINGLE CHANNEL DS3/E3 FRAMER WITH HDLC CONTROLLER
REV. 1.2.1
Bit 2 - LOF (Loss of Frame) Interrupt Status
This Reset-upon-Read bit-field will be set to "1" if a Change in LOF Condition interrupt has occurred since the
last read of this register.
The Receive DS3/E3 Framer block will generate the Change in LOF Condition interrupt in response to either of
the following two occurrences.
1. Whenever the Receive DS3/E3 Framer block transitions from the OOF Condition state into the LOF Condi-
tion state, within the E3 Framing Acquisition/Maintenance algorithm (per Figure 182).
2. Whenever the Receive DS3/E3 Framer block transitions from the FA1, FA2 Octet Verification state to the
In-frame state, within the E3 Framing Acquisition/Maintenance algorithm (per Figure 182).
Bit 1 - LOS (Loss of Signal) Interrupt Status
This Reset Upon Read bit will be set to "1", if the Receive DS3/E3 Framer block has detected a
Change in the LOS Status condition, since the last time this register was read. This bit-field will be asserted
under either of the following two conditions:
1. When the Receive DS3/E3 Framer block detects the occurrence of an LOS Condition (e.g., the occurrence
of 32 consecutive spaces in the incoming E3 data stream), and
2. When the Receive DS3/E3 Framer block detects the end of an LOS Condition (e.g., when the Receive
DS3/E3 Framer block detects a string 32 bits that does not contain a string of four consecutive "0’s").
The local µP can determine the current state of the LOS condition by reading bit 4 of the Rx E3 Configuration
and Status Register (Address = 0x11).
NOTE: For more information in the LOS of Signal (LOS) Alarm, refer to Section 6.3.2.6.
Bit 0 - AIS Interrupt Status
This Reset Upon Read bit field will be set to "1", if the Receive DS3/E3 Framer block has detected a Change in
the AIS condition, since the last time this register was read. This bit-field will be asserted under either of the
following two conditions:
1. When the Receive DS3/E3 Framer block first detects an AIS Condition in the incoming E3 data stream.
2. When the Receive DS3/E3 Framer block has detected the end of an AIS Condition in the incoming E3 data
stream.
The local µP can determine the current state of the AIS condition by reading bit 3 of the Rx E3 Configuration
and Status Register (Address = 0x11).
NOTE: For more information on the AIS Condition, refer to Section 6.3.2.6.2.
2.3.3.6 Receive E3 Interrupt Status Register 2 (E3, ITU-T G.832)
RxE3 Interrupt Status Register 2 (Address = 0x15)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Not Used
TTB
Change
Interrupt
Status
Not Used
FEBE
Interrupt
Status
FERF
Interrupt
Status
BIP-8
Error Interrupt
Status
Framing
Byte Error
Interrupt
Status
RxPld
Mis
Interrupt
Status
RO
RUR
RO
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
Bit 6 - TTB Change Interrupt Status (Receipt of New Trail Trace Buffer Message interrupt)
This Reset-upon-Read bit-field will be set to "1" if a Receipt of New Trail Trace Buffer Message interrupt has
occurred since the last read of this register.
The Receive DS3/E3 Framer block will generate the Receipt of New Trail Trace Buffer Message interrupt, if it
receives an E3 frame in which the value of the TR byte-field is of the form "1xxxxxxxb". A TR byte-field value of
this form is identified as the frame start marker.